Stainless Steel

Bushfire Mesh

Wildfire Defense Mesh meets the testing requirements of the California Building Code, Chapter 7A 706A.2 and is tested to UL723 / ASTM E84 meeting the requirements of a Class A Fire Rated Building Product

Ember Stop TOUGH

Wildfire Defense Mesh

Parent Product Code USSWOB 00657

Malleable
Cut with Tin Snips

Aperture 0.0647” / 1.67mm
Wire Diam 0.0177” / 26 SWG / 0.45mm
Open Area 62%

Common Applications

  • Vents & Weepholes
  • Enclosing Decks, Patios and Subfloor Spaces
  • Gutter Guard
  • Screens for Windows & Doors
  • Roofs and Birdstop
  • Eaves & Awnings
  • Perimeter Fencing
Add to Quote

For sheet or multiple roll orders contact [email protected] or 1300 304 316 as order is too large for courier.

Edit Content

1.23 mm

Aperture

0.18 mm

Wire Diameter

Stocked

Stock Status

Black

Powder Coat Finish

Plain Weave

Weave Type

0.3 kg/m2

Approx Kg/m2

76%

Approx % open area*

* Pre-black power coat finish.

HIGHER TENSILE WOVEN WIRE

  • Intercrossing wires will not break
  • Memory recognition allows it to stay flat
  • Inland 314 and coastal 316 grades available
PRODUCT CODE Grade Width mm Approx Weight Kg
SSWO 01670 0914 304 915 34
SSWO 01670 0916 316 915 34
SSWO 01670 1244 304 1245 46
SSWO 01670 1246 316 1245 46
SSWO 01670 1554 304 1550 58
SSWO 01670 1556 316 1550 58
SSWO 01670 1836 30^ 316 1830 68

0.0657” / 1.67mm

Aperture

0.0177” / 26 SWG / 0.45 mm

Wire Diameter

Stocked

Stock Status

Black

Powder Coat Finish

Plain Weave

Weave Type

0.2539 lbs/ft2 / 0.3 kg/m2

Approx Weight

62%

Approx % open area*

* Pre-black power coat finish.

HIGHER TENSILE WOVEN WIRE

  • Intercrossing wires will not break
  • Memory recognition allows it to stay flat
  • Grade 316  / 304
PRODUCT CODE Roll Length U.S / Metric Width U.S / Metric Approx Weight/Roll U.S / Metric
USSWOB 00657 0756 100 100′ / 30m 7.5″ / 190 mm 15.43 lbs / 7 Kg
USSWOB 00657 3606 50 50′ / 15 m 36″ / 915 mm 37.48 lbs / 17 Kg
USSWOB 00657 3606 100 100′ / 30 m 36″ / 915 mm 74.86 lbs / 34 Kg
USSWOB 00657 4906 50 50′ / 15 m 49″ / 1245 mm 50.71 lbs / 23 Kg
USSWOB 00657 4906 100 100′ / 30 m 49″ / 1245 mm 101.41 lbs / 46 Kg
USSWOB 00657 6006 50 50′ / 15 m 60″ / 1550 mm 63.93 lbs / 29 Kg
USSWOB 00657 6006 100 100′ / 30 m 60″ / 1550 mm 127.87 lbs / 58 Kg
USSWOB 00657 0756 50 50' / 15m 7/5" / 190mm 7.72 lbs / 3.5kg
Edit Content
Edit Content

Flame and Ember Resistant Vent

Chapter 7A, 706A2

Wildfire Defense Mesh meets the requirements of the CBC, Chapter 7A 706A.2 when tested to ASTM E2886 (Vertically Installed)

Off Ridge and Ridge Vents

Chapter 7A, 706A2.1

Wildfire Defense Mesh meets the requirements of the CBC, Chapter 7A 706A.2 – Off Ridge and Ridge Vents

Edit Content

Class A Fire Rated Building Product

Surface Burning Characteristics of Building Materials

UL 723 / ASTM E84
30 minute Test

Flame and Ember Resistance

Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame Impingement (Vertical)

ASTM E2886

Flame Impingement

Fire Test on Non-Mechanical
Fire Dampers Used in Vented Construction (Vertical)

ASTM E2912-17

Edit Content

Stainless Steel Woven Mesh Standards

SS Chemical Composition
ASTM – A580

SS Woven Mesh
ASTM E2016-15

Corrosion Test

SS Corrosion Resistance
AS/NZS 2331

Edit Content

Bushfire Test & Standards

Aperture Dimensions
AS 3959

Non Flammable Material
SD 1530.3

Edit Content

Ember Attack

Play Video

University of Southern Queensland (USQ)
Report No: Project 1007952

Radiant Heat

CSIRO
QAI Laboratories

Flame

Report No FCO-3313
ISO Accredited 17025

Edit Content

Wildfire Defense Mesh complies with the following Regulators & Stakeholders requirements in combating the threat of wildfires

  • International Wildland-Urban Interface Code (IWUI)
  • International Association of Wildland Fire (IAWF)
  • Austin Wildland Urban Interface Code
  • IBHS, Wildfire Prepared Home
  • NFPA & Firewise recommendations
  • CAL FIRE Home Hardening Recommendations
  • Living With Fire Home Hardening Recommendations
  • Building Council of Australia for Building in a Bushfire Prone Area
  • CSIRO
  • Rural Fire Service (NSW)
  • Victoria Building Authority
  • Queensland Reconstruction Authority, Queensland Government
Edit Content

Frequently Asked Questions

At Wildfire Defense Mesh, we get a lot of commonly asked questions about our range of products and their many applications.
This FAQ page lists those frequently asked questions. If your question is not answered here, please do not hesitate to contact us for help.

 

Edit Content

Australian Standards 3959 – Construction of Buildings in Bushfire Prone Areas and the different Wildland Urban Interface (WUI) Building Codes in the U.S., CA Building Code, IWUIC, NFPA, etc. are all based on similar research. Embers are 80-90% of the cause for building loss, followed by radiant heat and direct flame.

A homeowner cannot control the land and vegetation outside of their property boundary. Therefore, codes make us look to what we can control. As a building code generally take years to write and update, we now look to National and State Fire Authorities for Best Practice.

The current best practice are to develop layers of defense, being Home Hardening and creating Defensible Space to be part of your solution to protect your home and assets.

Edit Content

While many different local governments may have their iterations of wildfire codes or recommendations. These are likely derived from the three most widely implemented wildfire codes, being:

  • The International Code Council’s International Wildland Urban Interface Code (IWUIC),
  • The National Fire Protection Association’s Standard for Reducing Structure Ignition Hazards from Wildland Fire (Standard 1144), and
  • The California Building Code Chapter 7A — Materials and Construction Methods for Exterior Wildfire Exposure.
Edit Content
  • Stainless steel has a high melting point and the research states that the protection should be able to withstand 900+ degrees C where as aluminium Melts at 700 Degrees C
  • Stainless steel is non corrosive and low maintenance where as galvanised steel loses its non corrosive protection over time
  • Stainless steel is non combustible and will not increase your building fire load
  • Stainless steel can reflect Radiant heat resulting in a lower temperature on the non fire side. This lower temperature will reduce the likelihood of fire continuing beyond the barrier
Edit Content
  • When there is no fire situation:
    The Bushfire Mesh (woven mesh) allows airflow and will allow areas that get wet to dry out
  • When there is a Fire situation:
    The Bushfire Mesh (woven mesh) allows airflow and the mesh acts as a filter that “knocks out” embers as they are carried by the winds
  • Solid metal barriers deflect the wind up and over the fence leaving the ember in the wind allowing the ember to enter the defendable space
  • Solid fences require large footings as they are subject to the full force of the wind
  • Woven Mesh is strong and it keeps its shape
Edit Content
  • It is manufactured to ISO 9000 Quality Standards
  • It is strong and can keep animals and insects out of protected spaces
  • Available in black powder coated finish and blends into the environment
  • Provides a privacy feature when installed
  • Supplied with additional wires, top and bottom to make securing easy
  • Has been independently tested and passed Australian Standards and U.S. Standards
  • Meets the requirements per International Wildland Urbane Interface Code (2015)
  • Class A Fire Rated Product per UL 723 / ASTM E84
Edit Content

The Wildfire Defense Mesh house on the hompage is a great resources and tools to select the most appropriate width for your application. Before you install Wildfire Defense Mesh, you will need to consult and confirm with NFPA / Firewise, State or you Local Fire Authority home hardening guidelines or a Wildfire Home Assessment specialist

Remember Wildfire Defense Mesh is part of your wildfire solution for Home Hardening and Defensible Space.

REQUEST A QUOTE

Complete the form below and we will get back to you as soon as possible.

Quote information

Your quote is currently empty.

Return To Shop

Request a Quote

Quote information

Your Details
Application

Bushfire Mesh Width

Quantity 50' Rolls
 
Intended Use

Sample Details
Please note samples are approx 100 x 100 mm and availability is subject to specification.

Request a Quote

Complete the form below and we will get back to you as soon as possible.

Quote information

Your quote is currently empty.

Return To Shop